Kenworth C500

Kenworth C500

Published
2001-02-08
Model years
1999–2001

On certain vehicles, the main cab power and battery leads were attached incorrectly to the same side of the 135A circuit breaker when this circuit breaker was mounted in the optional firewall location rather than in the standard battery box location. This condition resulted on the main cab power circuit being unprotected. If a wiring short occurred anywhere along the cab power circuit, the available battery power could arc and cause a possible fire. Correction: Vehicles will be inspected and wiring corrected as required.

View the official source notice →

Kenworth T600

Published
2001-02-08
Model years
1999–2001

On certain vehicles, the main cab power and battery leads were attached incorrectly to the same side of the 135A circuit breaker when this circuit breaker was mounted in the optional firewall location rather than in the standard battery box location. This condition resulted on the main cab power circuit being unprotected. If a wiring short occurred anywhere along the cab power circuit, the available battery power could arc and cause a possible fire. Correction: Vehicles will be inspected and wiring corrected as required.

View the official source notice →

Kenworth T800

Published
2001-02-08
Model years
1999–2001

On certain vehicles, the main cab power and battery leads were attached incorrectly to the same side of the 135A circuit breaker when this circuit breaker was mounted in the optional firewall location rather than in the standard battery box location. This condition resulted on the main cab power circuit being unprotected. If a wiring short occurred anywhere along the cab power circuit, the available battery power could arc and cause a possible fire. Correction: Vehicles will be inspected and wiring corrected as required.

View the official source notice →

Kenworth W900

Published
2001-02-08
Model years
1999–2001

On certain vehicles, the main cab power and battery leads were attached incorrectly to the same side of the 135A circuit breaker when this circuit breaker was mounted in the optional firewall location rather than in the standard battery box location. This condition resulted on the main cab power circuit being unprotected. If a wiring short occurred anywhere along the cab power circuit, the available battery power could arc and cause a possible fire. Correction: Vehicles will be inspected and wiring corrected as required.

View the official source notice →